Four code rules decide whether a basement room can be a bedroom: an escape opening, ceiling height, smoke alarms and carbon monoxide alarms. Corner Canyon Basements is the referral service that connects Draper homeowners with the licensed local contractors who build to them.
1. The escape opening
The 2021 International Residential Code, as adopted in Utah, requires an emergency escape and rescue opening in each basement bedroom (R310.1 on UpCodes, a third-party copy of the code). Utah's amendment extends this to any new bedroom or accessory dwelling unit created in an existing basement (R310.7 on UpCodes, a third-party copy of the code). The window must have a net clear opening of at least 5.7 square feet (5 square feet for a grade-floor opening), at least 24 inches high and at least 20 inches wide, with the bottom of the opening no more than 44 inches off the floor.
The full set of numbers, including the window well, is on the egress windows page. Cutting a foundation wall is structural work for a licensed contractor.
2. Seven feet of ceiling
The IRC requires a ceiling height of at least 7 feet in habitable space (R305.1 on UpCodes, a third-party copy of the code). A basement with habitable space may have beams, girders and ducts project down to within 6 feet 4 inches of the floor. Draper City's basement submittal sheet asks for a cross-section showing ceiling, fur-down and soffit heights. It says surface-mounted lighting cannot encroach into the 7-foot minimum (Draper City Building Division). Rules change, so confirm with the Building Division at (801) 576-6399.
A flush-mount fixture hung from a 7-foot ceiling is a ceiling lower than 7 feet. Ask the contractor which light fixtures the design uses and how tall the room is where the ducts run.
3. Smoke alarms
Smoke alarms go in each bedroom, outside each sleeping area and on each story of the home, including the basement (R314.3 on UpCodes, a third-party copy of the code). Alarms in one home must be interconnected, so one alarm sets off all of them. Listed wireless alarms are allowed (R314.4 on UpCodes, a third-party copy of the code).
Utah amended the code so that when a permitted alteration, repair, addition or accessory dwelling unit is done, the whole dwelling unit gets smoke alarms placed as required for a new home (R314.2.2 on UpCodes, a third-party copy of the code). A basement bedroom permit can therefore change the alarms upstairs too.
4. Carbon monoxide alarms
Utah amended R315.3 so carbon monoxide alarms go on each level of the dwelling unit as well as outside each sleeping area (Utah Code 15A-3-202). On a basement with a bedroom, that covers the basement level and the area outside the bedroom; ask the contractor to show each alarm on the plan. Electrical alarm wiring is work for a licensed electrician.
The permit is part of the bedroom
Draper City requires a building permit for home work such as basement finishes (Draper City). Draper's basement submittal sheet asks plans to identify emergency egress from bedrooms and from the basement areas the project affects. Label each room's intended use on the plans. The permits page has the steps. The Building Division sets the full list of requirements, and rules change, so confirm yours at (801) 576-6399.
Why it matters at resale
A bedroom with no legal escape window can cause trouble when you sell. For what the Salt Lake City Cost vs Value figures cover, a job the report defines as an entertaining area, a wet bar and a bathroom, and what they say about resale, see the cost page.
Questions for the contractor
- Which rooms on the plan can legally be bedrooms?
- What will each escape window and well cost, as its own line?
- How tall is the ceiling where the ducts run, and where do soffits go?
- Who places and wires the smoke and carbon monoxide alarms, and will they be interconnected?
- Does the permit include the alarms on the upper floors?
- Who pulls the permit, and will the room be labeled a bedroom on the plans?
Common questions
Does a closet make it a bedroom?
Ask the Building Division at (801) 576-6399 what a room needs before it is labeled a bedroom on the plans. The escape opening, the ceiling and the alarms are the requirements above.
What if the basement already has a bedroom with a small window?
It does not always have to change. Utah's R102.7.2 says an existing bedroom whose egress window met the code in force when it was finished does not have to be physically changed if the change would compromise the structure or could not meet other rules such as setbacks and window wells (Utah Code 15A-3-202). The Building Division can say how that applies to your room.
Where these numbers come from
The ceiling and egress submittal items are from Draper's basement submittal sheet, and the code rules from UpCodes' third-party copy of the Utah-amended IRC, read in November 2026.