5.7 square feet. That is the minimum net clear opening for a basement escape window under the 2021 International Residential Code as adopted in Utah (R310.2.1 on UpCodes, a third-party copy of the code). A new basement bedroom needs an escape opening at least that size, or 5 square feet for a grade-floor opening. Corner Canyon Basements is a referral service that connects Draper homeowners with the licensed local contractors who cut and set these windows.
The six numbers on the window
All six come from the 2021 IRC chapter 3 as adopted in Utah (UpCodes, a third-party copy of the code).
| Rule | Number |
|---|---|
| Net clear opening, area | at least 5.7 square feet (5 for a grade-floor opening) |
| Net clear opening, height | at least 24 inches |
| Net clear opening, width | at least 20 inches |
| Bottom of the opening above the floor | no more than 44 inches |
| Window well, area | at least 9 square feet |
| Window well, projection and width | at least 36 inches |
A window well deeper than 44 inches also needs a permanently fixed ladder or steps (IRC R310.4.2).
Why 24 by 20 is not enough
The height and width minimums are separate from the area minimum. A 24-inch-high opening that is 20 inches wide is 480 square inches, or about 3.3 square feet. The area rule needs 5.7 square feet, which is about 821 square inches. At 24 inches high, the opening must be at least 34.2 inches wide. At 20 inches wide, it must be at least 41.1 inches high. That is arithmetic on the code's figures, so ask for the window's measured net clear opening.
"Net clear opening" means what is left when the sash is open, not the size of the glass. A contractor measures it on the open window. Ask for that measurement in writing before you buy.
When a room needs one
The IRC requires at least one operable emergency escape and rescue opening in a basement, and where a basement has bedrooms, one in each bedroom (R310.1 on UpCodes, a third-party copy of the code). Utah's amended R310.7 applies the requirement to any new bedroom or accessory dwelling unit created in an existing basement.
Utah also added a rule for existing bedrooms. If a bedroom's egress window met the code in force when the bedroom was finished, it does not have to be physically changed when the change would compromise the structure or could not meet other rules such as setbacks and window wells (Utah Code 15A-3-202, R102.7.2). That rule protects an old bedroom. It does not excuse a new one.
What the contractor does
This is the dirtiest and most structural step in a basement finish. A licensed contractor cuts the foundation wall, sets a header where one is needed, installs the window, then digs and sets the well. A cut that widens an existing opening may need an engineer. Nothing here is a do-it-yourself job.
Snow usually falls regularly in Draper from November through March (Wikipedia). A well collects snow and meltwater, so ask the contractor how the well drains and how a ladder or steps will work in winter.
What Draper's plan review asks to see
Draper City's basement submittal sheet says plans must identify emergency egress from bedrooms and from the basement areas the project affects (Draper City Building Division). It also says all projects are designed to the currently adopted IRC, IBC and NEC. For exactly what the Building Office wants on the plans for a window and well, call it at (801) 576-6399. Rules change, so confirm before you order a window. The permits page lists the other submittal items.
Questions to ask
- What net clear opening will the window have, measured open?
- Is the bottom of the clear opening 44 inches or less above the floor?
- How big is the well, and does it need a ladder?
- Will an engineer review the cut?
- Who pulls the permit, and is the window on the plans?
Common questions
Can a bedroom go in the basement without an egress window?
Not under the code. The IRC requires an escape opening in each basement bedroom. Utah's amendment applies that to new bedrooms in existing basements. A room without one is a den, an office or storage, and the bedroom page explains what else a legal bedroom needs.
What does an egress window cost?
The price depends on the wall, the soil, the well and whether an engineer is involved. Ask for it as its own line on the quote. The cost page has the Salt Lake City benchmark and how to compare bids.
Can the same window serve two rooms?
The code ties an opening to each sleeping room. Ask the contractor and the Building Division how your plan is read.
Where these numbers come from
The window and well figures come from UpCodes' third-party copy of the 2021 IRC and the plan-review items from Draper's basement submittal sheet, read in November 2026.